|
Quality
First™ Forced Air Guidelines
Manual
Price:
TECA Members:
$70.00
Others: $87.00
Shipping & Handling: $20.00
This manual was designed for use with
TECA's Quality First™ Forced
Air Guidelines Course.
5th Edition, January 2008
ISBN: 978-0-9809333-0-7
144 pages, loose-leaf binder format
Gain a thorough understanding of the
process of sizing and installing a forced
air system including heat loss/heat gain
calculations, equipment selection and
duct sizing. Now with heat gain, heat
pump selection and low pressure duct
tables. All
calculations, charts & tables are
in Imperial units.
The Forced Air
Guidelines Manual includes:
- Installation Requirements: per
Gas Code, Building Code and equipment
manufacturer. Includes a System Completion
Checklist.
- Heat Loss/Heat Gain, Appliance
Selection and Duct Sizing: Worksheets,
explanatory text and charts, tables
and drawings for heat loss/heat gain,
equipment selection to dwelling load
requirements and duct sizing tables
(both 0.3"wc ESP and 0.2"wc
ESP) and system layout to selected
equipment requirements.
- Examples of Worksheet Use: elevations,
floor plans, alternate heat loss methods,
cfm distribution, appliance selection,
duct system layout on plans, system
summary sheets and explanatory notes.
- Retrofit Worksheets: Supply
Air and Return Air System evaluation
worksheets and a Customer Summary form.
- Appendix including
R-Value tables, HTM calculation, equivalent
lengths, duct sizing and round to rectangular
duct conversion charts, meter clocking
tables/procedures and more.
Development of the new heat gain/heat
pump material (added in 2006) was funded
in part by the BC Ministry of Energy,
Mines & Petroleum
Resources under the Energy
Efficient Buildings program.
The development of minimum standards for
the correct sizing, design and installation
of high efficiency equipment and systems
is the basic building block to the achievement
of the government's target reductions in
energy consumption.
To order, please select one of the options
above. For bulk orders, please contact
us to send a purchase order.
Please allow up to 2 weeks for delivery.
DISCLAIMER: This Manual was developed
in consultation with, and using information
obtained from manufacturers, suppliers,
contractors and others with specialized
experience. It is subject to revision
as further use and investigation may
show such revision necessary or desirable.
Installations and designs that comply
with this manual will not necessarily
be acceptable if, when examined and tested,
they are found to have features that
impair the result contemplated by these
requirements. The authors and editors
assume no responsibility and accept no
liability for the application of the
principles or techniques contained in
this manual or for errors or omissions
and expressly disclaim any such responsibility. |
Quality
First™ Forced Air Guidelines
Software
Price:
TECA Members: $104.00
Others: $131.00
Shipping & Handling: $15.00
There are two programs for Forced Air: Heat
Loss/Heat Gain and Duct
Sizing. Both are intended
for use with TECA's Quality
First™ Forced Air
Guidelines manual. Available on CD
(by regular mail only) or electronically
via e-mail. (Download option coming
soon!)
NOTE: You must have
Microsoft Excel™ 97
(or newer) spreadsheet software on your
computer to run these programs.
Heat Loss/Heat Gain Program Features
- Calculates room-by-room, floor-by-floor
or whole house heat loss & heat
gain for up to 36 separate rooms or
areas.
- Heat Loss Summary Sheet with
room-by-room cfm distribution and alternate
(electric, gas fireplace, wood) heat
source load calculations.
- Heat Gain Worksheets include
features such as the ability to rotate
the orientation of the house to 8 cardinal
points, shade coefficients, window
coverings & automatic latitude
adjustment factors.
- Balance Point Worksheet for
Heat Pumps
- Appliance Selection Worksheet used
to select a heating appliance properly
sized to heat loss & heat gain
calculations.
- NEW: 2-stage heating, A/C coil and
heat pump options.
Duct Sizing Program
Features
- For residential and light commercial
installations, up to 5000 CFM, up
to 36 x 18 trunk duct size.
- Supply Air System Worksheet calculates
trunk and run sizes either for room-by-room
cfm requirements or by run size and
number of fittings.
- Return Air System Worksheet—Enter
codes from SA Worksheets for automatic
calculations of Return Air trunk, run,
drop and grills.
- Energy Use Worksheet—calculates
annual fuel consumption and heating
costs for various fuels. A great selling
tool!
- Up to 280 possible duct runs and
up to 5 branch ducts (connect to trunk
or other branch ducts).
- NEW: Choice of 0.2"wc or 0.3"wc
static pressure systems.
- Re-designed layout with more space
for rooms & comments.
IMPORTANT: Please provide your name, company, and address as you wish them to appear on your Forced Air Guidelines documents. This information will be locked into the program and there is a fee to re-issue with any changes. Ordering on behalf of a large company? Please be advised that if you are ordering from a large company the program can have multiple users (up to 4). Separate branches will require their own copy. It is copyright infringement to copy TECA software.
Please select
one of the options above to
place your order.
|